Easy to install
Push-through and wall mounting
Side-by-side mounting possible for both
Compact installation allows smaller cabinets to be used
Push-through mounting allows the cabinet to be cooled more easily
Frame sizes FSAA, FSAB and FSAC (230 V 1 AC) are significantly smaller compared to the previous frame sizes FSA and FSB within the same power range
Plug & Play
Can be run "out-of-the-box" without other options
Basic operator actions at a built-in BOP (Basic Operator Panel)
Connection of SINAMICS V20 with USS or Modbus RTU via terminals
Easy integration into existing systems
Easier commissioning through standard libraries and connection macros
Full flexibility of Modbus RTU settings widens communication with controller
Simple connection to a control system (e.g. SIMATIC S7 PLC via Modbus RTU/USS)
Integrated Braking Module
Converters ≥ 7.5 kW (frame sizes FSD and FSE) have an integrated Braking Module. In this case, the braking resistor can be directly connected. The dynamic energy is dissipated as heat in a braking resistor with an adjustable duty cycle of between 5 % and 100 %.
Possible to use dynamic braking to increase braking performance
EMC category C1
The devices are optionally available with an integrated RFI suppression filter, enabling compliance with the radio interference limit values laid out in IEC 61800‑3 category C1 when installed in the control cabinet in an EMC-compliant manner. Frame sizes FSAA, FSAB and FSAC therefore satisfy the radio interference requirements for industrial applications as well as for use in residential and business environments, including commercial applications such as refrigerated counters, fitness equipment, ventilation systems, industrial washing machines, etc.
6ES7288-1SR20-0AA0 | S7-200 SMART,CPU SR20,标准型 CPU 模块,继电器输出,220 V AC 供电,12 输入/8 输出 |
6ES7288-1ST20-0AA0 | |
6ES7288-1SR30-0AA0 | |
6ES7288-1ST30-0AA0 | S7-200 SMART,CPU ST30,标准型 CPU 模块,晶体管输出,24 V DC 供电,18 输入/12 输出 |
6ES7288-1SR40-0AA0 | S7-200 SMART,CPU SR40,标准型 CPU 模块,继电器输出,220 V AC 供电,24 输入/16 输出 |
6ES7288-1ST40-0AA0 | S7-200 SMART,CPU ST40,标准型 CPU 模块,晶体管输出,24 V DC 供电,24 输入/16 输出 |
6ES7288-1SR60-0AA0 | S7-200 SMART,CPU SR60,标准型 CPU 模块,继电器输出,220 V AC 供电,36 输入/24 输出 |
6ES7288-1ST60-0AA0 | S7-200 SMART,CPU ST60,标准型 CPU 模块,晶体管输出,24 V DC 供电,36 输入/24 输出 |
6ES7288-1CR40-0AA0 | S7-200 SMART,CPU CR40,经济型 CPU 模块,继电器输出,220 V AC 供电,24 输入/16 输出 |
6ES7288-1CR60-0AA0 | S7-200 SMART,CPU CR60,经济型 CPU 模块,继电器输出,220 V AC 供电,36 输入/24 输出 |
6ES7288-2DE08-0AA0 | S7-200 SMART,EM DI08,数字量输入模块,8 x 24 V DC 输入 |
6ES7288-2DR08-0AA0 | S7-200 SMART,EM DR08,数字量输出模块,8 x 继电器输出 |
6ES7288-2DT08-0AA0 | S7-200 SMART,EM DT08,数字量输出模块,8 x 24 V DC 输出 |
6ES7288-2DR16-0AA0 | S7-200 SMART,EM DR16,数字量输入/输出模块,8 x 24 V DC 输入/8 x 继电器输出 |
6ES7288-2DT16-0AA0 | S7-200 SMART,EM DT16,数字量输入/输出模块,8 x 24 V DC 输入/8 x 24 V DC 输出 |
6ES7288-2DR32-0AA0 | S7-200 SMART,EM DR32,数字量输入/输出模块,16×24 V DC 输入/16 x 继电器输出 |
6ES7288-2DT32-0AA0 | S7-200 SMART,EM DT32,数字量输入/输出模块,16 x 24 V DC 输入/16 x 24 V DC 输出 |
6ES7288-3AE04-0AA0 | S7-200 SMART,EM AI04,模拟量输入模块,4 输入 |
6ES7288-3AQ02-0AA0 | S7-200 SMART,EM AQ02,模拟量输出模块,2 输出 |
6ES7288-3AM06-0AA0 | S7-200 SMART,EM AM06,模拟量输入/输出模块,4 输入/2 输出 |
6ES7288-3AR02-0AA0 | S7-200 SMART,EM AR02,热电阻输入模块,2 通道 |
6ES7288-3AT04-0AA0 | S7-200 SMART,EM AT04,热电偶输入模块,4 通道 |
6ES7288-5CM01-0AA0 | S7-200 SMART,SB CM01,通信信号板,RS485/RS232 |
6ES7288-5DT04-0AA0 | S7-200 SMART,SB DT04,数字量扩展信号板,2 x 24 V DC 输入/2 x 24 V DC 输出 |
6ES7288-5AQ01-0AA0 | S7-200 SMART,SB AQ01,模拟量扩展信号板,1 x 12 位模拟量输出 |
6ES7288-5BA01-0AA0 | S7-200 SMART,SB BA01,电池信号板,支持普通纽扣电池 |
6AV6648-0BC11-3AX0 | SMART LINE,Smart 700 IE,7 寸,64 K 色真彩显示,集成以太网接口 |
6AV6648-0BE11-3AX0 | SMART LINE,Smart 1000 IE,10.2 寸,64 K 色真彩显示,集成以太网接口 |
6ES7288-0CD10-0AA0 | S7-200 SMART AC 100-240 V OUTPUT: DC 24 V/3 A |
6ES7288-0ED10-0AA0 | S7-200 SMART AC 100-240 V OUTPUT: DC 24 V/5 A |
6EP1332-1LA10 | SITOP PS207 24 V/4 A 100-240 V AC (110-300 V DC) OUTPUT: 24 V DC/4 A |
6ES7288-3AE08-0AA0 | 模拟量8路输入 |
ET 200M 站出现故障时,I/O 不在可用。 安全相关信号模块将被禁用。
冗余切换式 I/O,用于 S7-400FH工厂需要使用安全型控制器。CPU 侧和 I/O 侧需实现容错功能。需要下列部件:
2 个 CPU S7‑400H,带 F‑Runtime 许可证
2 条 PROFIBUS DP 总线。
2 个 ET 200M ,带 2 个 IM 153-2(冗余)。
冗余型安全相关信号模块。
CPU、IM 153-2、PROFIBUS DP 总线、安全相关信号模块或 ET 200M 站出现故障时,控制器仍然保持可用。
通信中央控制器与 ET 200M 之间的标准通信和安全相关通信是通过 PROFIBUS DP 实现的。 专门为安全相关通信制定的 PROFIsafe 行规支持在标准数据报文中传输用于安全功能的用户数据。 无需附加的硬件组件,如专用安全总线。所需的软件既可以作为一个操作系统的扩展功能集成在硬件组件中,也可以作为一个软件块装载到 CPU 中。
功能S7-400F/FH 满足下列安全要求:
安全等级 AK 1 至 AK 6,符合 DIN V 19250/DIN V VDE 0801
安全等级 SIL 1 至 SIL 3,符合 IEC 61508
安全类别 1 至 4,符合 EN 954-1
工作模式S7-400F/FH 的安全功能包含在 CPU 的 F 程序中,并且包括在安全相关信号模块(F 模块)内。
信号模块采用差异分析方法和测试信号注入技术实现输出和输入信号的监控。
借助周期性自检、指令检测、程序逻辑检测和程序顺序流检测等方法,CPU可以检测控制器是否工作正常。此外,通过“活跃标志(sign-of-life)”请求,还可以对I/O进行检测。
若判定系统中存在故障,则将该系统切换至安全状态。
- 西门子6ES7288-1ST40-0AA0 2024-11-21
- 西门子6ES7288-1SR40-0AA0 2024-11-21
- 西门子6ES7288-1ST30-0AA0 2024-11-21
- 西门子6ES7288-1ST20-0AA0 2024-11-21
- 西门子6ES7288-1SR20-0AA0 2024-11-21
- 西门子SITOP开关电源6EP1334-2AA00 2024-11-21
- 西门子SITOP开关电源6EP1333-3BA00 2024-11-21
- 西门子SITOP开关电源6EP1333-2BA20 2024-11-21
- 西门子SITOP开关电源6EP1333-2BA01 2024-11-21
- 西门子SITOP开关电源6EP1333-2BA00 2024-11-21